Sampling Pump, Model MP-W5P

製品カタログ

このカタログについて

ドキュメント名 Sampling Pump, Model MP-W5P
ドキュメント種別 製品カタログ
ファイルサイズ 1.4Mb
取り扱い企業 柴田科学株式会社 (この企業の取り扱いカタログ一覧)

この企業の関連カタログ

この企業の関連カタログの表紙
Viscosity Measurement Series
製品カタログ

柴田科学株式会社

この企業の関連カタログの表紙
Sampling Pump MP-ΣNIISeries
製品カタログ

柴田科学株式会社

この企業の関連カタログの表紙
ハンディ水質計「AQUAB(R)アクアブ」シリーズ 
製品カタログ

柴田科学株式会社

このカタログの内容

Page1

Sampling Pump, Model MP-W5P The MP-W5P Minipump is a portable air sampling pump equipped with functionality for measuring accumulated flowrates and constant flowrates. Its small, lightweight design is suitable for personal exposure measurements. Due to the fact that the flowrate can be set in a wide range from 0.05 L/min to 5.00 L/min, it can also be used for a variety of other purposes such as air sampling in each of occupational health, indoor and atmospheric environments. Air intake port O.D.: 6 mm and 8 mm Belt hook Used when mounting the pump on a belt Exhaust port The exhaust cannot be Power switch used for sampling. (Slide type) Battery cover Power connector Used to connect a recharger, AC adapter, or communication cables Tripod attachment hole (bottom) Features Specifications ●Thanks to the wide flowrate Item Code 080860-5050 settingsrange from 0.050 to 5.00 Model MP-W5P L/min, the ranges of all of the MP-∑NII Variable Flowrate Range 0.050 to 5.00 L/min series basic type minipumps Instantaneous Flowrate Display Range 0.000 to 6.50 L/min (30NII/300NII/500NII) can be covered 0.05L/min: 0 to 7.0kPa  1.0L/min: 0 to 10.0kPa by a single pump unit. Constant Flowrate 0.1L/min: 0 to 10.0kPa  1.5L/min: 0 to 10.0kPa Operational Range 0.5L/min: 0 to 10.0kPa  5.0L/min: 0 to 3.0kPa ●The constant flowrate function Flowrate Accuracy 5 mL or ±5 % of the specified flowrate value (whichever is larger) incorporated in the MP-W5P delivers comparable or better performance than Accumulate Flowrate Settings Range 0.0 to 9999.9 L the existing basic type MP-∑NII series (Volume Timer) minipumps (30NII/300NII/500NII). Integrated Flowrate Display Range 0.00 to 99999 L Time Setting and Display Range 0.00 to 999.59 (hours, minutes) ●Small/lightweight Built-in Flow Meter Differential pressure type The capacity is approximately 1/2 that Pump Type Diaphragm of the MP-∑NII series, and it is 200 g Pump head: PC and POMMaterials lighter. Diaphragm: EPDM Flow line: ABS Case: PC Measurement Mode Manual, countdown timer, volume timer ●In terms of operability, the MP-W5P Display LCD display (with backlight) pump has the same screen display and Air Intake Diameters O.D.: 6mm and 8mm (Tube used: 5mm or 7mm in I.D) the button operations as the MP-∑NII Ambient Temperature and Humidity Range 0℃to 40℃; 10 %RH to 90 %RH (no condensation) series. AC adapter (100 V AC) NiMH rechargeable battery Power Supply ● and six AA batteriesCompatible with three types of power supply The pump can be run using AC power, Operating Time (when unloaded and 0.1 L/min: 24 hours regular batteries (six AA batteries), or using the NiMH rechargeable battery) 1.0 L/min: 18 hours or longer an NiMH rechargeable battery. Dimensions W95×D56×H95 mm (not including protruding parts) The product includes an NiMH Weight 0.45 kg (including the NiMH rechargeable battery) rechargeable battery, a quick charger NiMH rechargeable battery (model NI-W5), quick charger with AC adapter (model QCA-W5), Accessories with AC adapter (model QCA-W5), and a battery holder (model SN3-6B), color caps (red, blue, yellow, one each) battery holder (model SN3-6B).
Page2

Optional and Spare Parts Example of How to Use the Optional and Spare Parts ■Example of How to Use ■Example of Operation  the Three-Color Caps  Connecting with the Battery  for the MP-∑N/∑NII Three-color caps Can be attached atop LI-10N battery unit Soft case Quick charger (model QCA-W5) the air intake port. Item Code Product Name 080860-5051 NiMH rechargeable battery, model NI-W5 080860-5052 Battery holder for the MP-W5P, model SN3-6B 080860-5053 Three-color caps: Red, blue, yellow, one each 080860-5054 Quick charger, model QCA-W5※1 080860-5055 Soft case for MP-W5P 080860-5056 Air intake port set for MP-W5P 080860-5057 Filter element VFE-2, set of 5※1 080860-58 Connection cable for LI-10N Connection cable 080860-010 LI-I0N Battery unit, model LI-10N※2 080860-110 Quick charger, model QC-10N※3 They can be used to distinguish The instrument can be operated for an ※1 Specifically designed for the MP-W5P. It cannot be used with the MP-∑N/∑II series minipumps. instruments by usage site or application. If extended period by connecting it externally ※2 See the option usage example at right regarding how to use the LI-I0N battery unit for the MP-∑ you attach a 7 mm dia. ×10 mm tube to the to the LI-10N battery for the MP-∑N/∑NII, N/NII series. Note that the QC-10N charger is required to charge the LI-I0N battery unit. air intake port and then use the color cap, it which has a larger capacity than the NI-W5 ※3 This charger is specifically for the LI-I0N battery unit. It cannot be used to charge the NI-W5 will help to prevent the tubing from coming battery provided as standard. battery. loose. Related Products PM4 Personal Dust Sampler Set Flow Calibrator, Model FC-M1 (for Minipumps) Using an inertia collision type particle size selector, the sampler It can automatically calibrate the intake flowrate for MP-Σ30NII, MP-Σ300NII, MP-Σ500NII, MP-Σ separates dust in accordance with the PM4 (50 % reduction in 4 μm 100HNII, and MP-W5P minipumps. It is also conveniently portable and can be used to check the particles) sizing characteristics. Coarse particles larger than PM4 are flowrate at the measurement worksite. collected by a stainless steel collection plate, and the PM4 particles are collected by a filter paper. As a result, the exposure to dust by working Features personnel can be measured both in terms of PM4 dust concentration and the total dust concentration. ●Easy-to-operate dry flowmeter ●You can select the flowrate display mode freely from <Application Example> the value converted based on temperature and atmospheric pressure (25 °C at 1 atm; 20 °C at 1 atm; 0 °C at 1 atm), or the actually measured Personal flowrate. sampler holder Specifications Item Code 080120-151 Model FC-M1 Measurement Range 0.05 to 5.00 L/min※2 MP-W5P Instantaneous Flowrate Display Range 0 to 6 L/min Flowrate Accuracy ±0.003 L/min or ±2 % of the standardflowrate (whichever is larger) Flowrate Detection Method Differential pressure detection Ambient Temperature 0℃ to 40℃; 10 %RH to 90 %RH and Humidity Range (no condensation) Power Supply 9 V DC (four AA alkaline batteries)【Connection Example】 Operating time of 8 hours or longer※2 Soft case included The MP-W5P pump can be calibrated with Dimensions W105 × D170 × H100 mm the combination of the flow calibrator Weight Approx. 900 g (including batteries) (model FC-M1) and the buffer tank. ※1 Actually measured or converted flowrates can be displayed. Connection tube※ Flowrate can be converted in terms of 25 °C at 1 atm, 20 °C at 1 Specifications atm, and 0 °C at 1 atm. The specified precision may not be achieved when operated at a site with a large difference between Item Code 080150-445 high and low temperatures. Filter Paper Holder NWPS-254: Plastic 25 mm dia., × 1 ※2 Approximation based on continuous operation using AA alkaline Sizing Characteristics PM4 (50 % reduction in 4μm particles) batteries at 25 °C Suction Pump Minipump, model MP-W5P Options Flowrate 2.5 L/min Weight Approx. 0.5 kg Buffer tank Item Code Product Name NWPS-254 personal sampler holder×1 FC-M1 MP-W5P 080120-1511 Soft case for FC-M1 MP-W5P Minipump × 1 080040-3212 AC adapter Composition Grease set (with spatula and micro-spatula) × 1; intermediate clip × 1 Communications cable 080880-1000 Buffer tank TF98 25-mm dia. fluoropolymer-coated fiberglass filter × 100 080880-10001 Middle tube for the buffer tank Toalon tube × 1 Soft case ※Provide a Toalon tube  (7 mm I.D.) if necessary. 080860-59 Communications cable; set of two types(1 cable for MP-W5P and 1 cable for MP-ΣNII) August, 2017.