Page1
MT-05U_1
MT-05U
Mask Fitting Tester
When wearing a dust protection mask, you need to select a mask that suits your face and wear it properly!!
What is a Fit Test?
A test, for selecting a mask
that fits an individual's face,
is called a Fit Test.
The MT-05U can perform this
fit test quantitatively.
Differences from previous
MT-05 model
● Daily check mode added
● Condensation reduction feature
enhanced
● PC communication capability added
● Soft case included as standard
● Particle generator available
(option)
What is a Fit Check?
When you use a mask selected
in a Fit Test, the routine check
to ensure that the mask fits well
each day, is called a Fit Check.
The MT-05U can perform the fit
check quantitatively.
Page2
MT-05U_2
What is a Mask Fitting Tester? Important points when wearing a mask
● A tester that counts the number of dust particles outside Make sure that the mask fits your face snugly and
and inside the mask, and obtains the penetration rate that you are not inhaling harmful dust or germs.
(leakage rate %) of dust into the mask.
First, perform a Fit Test
● The tester uses the dust floating in the room or sodium
chloride particles generated by a particle generator The size and shape of everybody's face are
(option) as test particles. We recommend that a particle different, and selecting a mask that suits each
generator is used when the dust particle count is low. individual is important for protecting their health. The MT-05U can perform a quantitative Fit Test
● A test guide or tube joint set is used to measure the mask that helps to select a mask, which fits each
leakage rate. individual.
Routine checks using Fit Check
Count the number of dust particles inside the mask
When using the selected mask each day, the
Count the number of dust particles outside the mask wearer checks how well the mask fits before
entering the workplace.
The MT-05U Mask Fitting Tester Capabilities
Before measurement using Selecting a mask that fits When you find a mask that When the mask does not fit
Fit Test mode..... your face...... fits your face ...... well ......
Check Measurement Quantitative Fit Tests Routine Checks Check Where Leak is Occurring
Environment and Tester Status Using Fit Test Mode! Using Fit Check Mode! Using Training Mode!
Using Daily Check Mode!
This is a measurement mode This is a measurement mode In this measurement mode, the
This mode checks whether for selecting a mask that matches that can perform a check in penetration rate of dust particles
the number of particles in the shape of your face by 30 seconds at the shortest into the mask can be easily
the measurement environment performing several specified using the test guide. Suitable displayed in real time using a test
is sufficient, and whether the exercises while a tube joint for routine checks of how well guide or tube joint set.
tester is operating normaly (or test guide) is attached. the mask fits. The fitness can be The fitting of the mask can be
when performing a Fit Test. Displays the measurement checked easily before going into checked at a glance as a number and
We recommend that you use results (leakage rate, and the workplace, and the person a bar graph.
a particle generator (option) protection factor or fit factor) wearing the mask can then go Ideal for checking and teaching
in environment where the for each specified exercise directly into the work area while how to wear a mask.
number of particles is small. and also for all exercises. still wearing the checked mask.
The MT-05U Can be Used in These Kinds of Locations! ■ To Reduce Condensation
Condensation may occur inside
Medical ● Selecting a N95 mask etc. that suits your face ● Training on how to fit and wear masks the tube when taking measurements. There is a slit on the side of
● Measure the protection factor of respirators used in areas that the MT-05 series, and by inserting
handle materials such as indium or refractory ceramic fibers a test guide, outside air can be Industrial ● Fit mask and perform a Mask Fit check before entering ventilated through the tube to
the workplace reduce condensation.In addition, on the MT-05U, the
● Education for workers who need instruction and training condensation reducing function
on how to fit and wear masks
Other can be performed automatically ● Selection of suitable masks at locations where filter without using a test guide.
performance must be demonstrated
Page3
MT-05U_3
Fit Test
This is a test to select a mask that (Example) In the case of the OSHA
fits your face. 29 CFR 1910.134 standard
Several types of specified exercises
are performed during measurement, The following specified exercises are performed for one minute each (⑥
and the measurement results for for 15 seconds), and measurements
each exercise and the overall result for each exercise are made.
are acquired. In addition to the
methods (protocols) described in the ①Normal breathing ⑤Talking
Japanese Industrial Standard (JIS), ②Deep breathing ⑥Grimace③Shaking head side to side⑦Bending over
protocols such as the US OSHA ④Moving head up and down⑧Normal breathing
protocols are included.
Basic Fit Check Procedure
① Put on the mask
② Insert the test guide, which is connected to the‘MASK’side,
between the face and the mask
③ Check the fitting of the mask again.
④ Hold the test guide connected to the‘OUTSIDE’side near the face
⑤ Press ‘START’ button (measurement can be taken in 30 seconds at the shortest!)
⑥ The pass/fail result and numerical results (count and fit factor) are displayed
on the screen.
⑦ If the check fails, re-check the fitting of the mask or replace the mask
with a different type or size and make the measurement again
● Two Types of Measurement
■ Test Guide (non-destructive mask test)
Because it does not require any processing such as
opening a hole in the mask (non-destructive mask test),
the wearer can enter the workplace directly with a mask
whose fit has been confirmed. It is suitable for routine
fit checks!
■ Tube Joint Set (open a mask hole)
Fixing the tube directly to the mask (open a mask hole) reduces the risk of Test Guide
the tube falling out of the mask during measurement.
It is suitable for a Fit Test mode that involves body movement during measurement.
Tube Joint Set
●Communication function between
PC and MT-05U
• The MT-05U can be controlled from a PC (up to 4 units can be connected
simultaneously).
• Information about a subject, who is being tested, and mask information
Fit Test Report
can be stored in a database.
• The set up enables the recording, browsing, and printing, etc. of measurement
results for each measurement mode.
• Measurement results can be saved
in CSV format and it is processed
Step Exercise Duration(Sec.) Fit Factor Result
using commercially available
spreadsheet software, such as
Excel.
Fit Test Card
Respirator Result
Example of printing measurement results
Set up example
Page4
MT-05U_4
Features
With a single detector (particle counter), MT-05U measures the Outside inlet Mask side inlet
number of particles in the room (outside the mask) and inside the mask
alternately to quantify how tightly the mask fits the face. As a result,
errors due to differences in detector characteristics are reduced.
There are four modes: Daily Check mode, Fit Test mode, Fit Check Exhaust
mode, and Training mode, that enable a user to use according Heater Touch panel RS-232C output
to the application.
Measurements can be made using a test guide (non-destructive Control circuit USB
mask test) or a tube joint set (open a mask hole). Solenoid
Flowmeter valve START button
Automatic recording function for measurement results (Daily Particle counter
Check mode, Fit Test mode, and Fit Check mode).
Needle
MT-05U communicates with PC using a USB cable. valve
Leakage rate can be measured while the fitting of the mask is Pump
checked by using attached mirror. Block diagram
■Main specifications
Item code 090200-08
Model MT-05U
Intended
measurement Mask-to-face fit evaluation
Measurement items Particle count, Leakage percentage, and Fit factor
Principle of Particle count concentration measurement by laser beam scattering
measureme nt (determination of dust particle count ratio between indoor air and in-mask air)
Measurement Counting range: 0 to 9999999 counts ranges Leakage percentage: 0 to 100% Fit factor: 1 to 1000000 Tube Joint Set Type M 100 pairs/set Tube Joint Attachment Tool
Suction flow ra te 1 L/min
Leakage percentage and Fit factor calculation functions; heating tube
Built-in functions temperature control function; dryer function; RS-232C output function; USB communication function; and logging function (up to 200 logs for each of Fit
Check, Fit Test, and Daily Check)
Usage environmen t 0 to 40°C, 30 to 90%RH (no condensation)
Power supp ly 100 to 240 ±10% VAC, 50/60 Hz, approx. 0.5 A
Main unit
dimension s 210 (W) × 240 (D) × 232 (H) mm (excluding protrusions)
Main unit mas s Approx. 3 kg
Accessorie s One AC adapter (fitted with a plug; supplied with four spare plugs)
Two pcs of Sampling tube (pair tube) 1.5 m
One strap clip Sampling tube (pair tube) Test Guide
One high-performance zero check filter
One Tube joint set type M 100 pairs/set
One Tube joint attachment tool type M
Two suction port caps
One external output connector cap
One USB connector cap
One CD-ROM (Communication software, USB driver, Operation manuals)
One USB cable (A-mini B)
One Soft case
One Manufacturer’s inspection and calibration certificate
● Safty standard : CE, FDA, Code 95R-EN, and not explosion proof.
● The above specifications and the accessories may be subject to change for improvement or other
reasons, provided that the functions and performance of the product are not affected.
■Consumables and spare parts
Item code Item name Particle Generator Salt Tablet
080200-0821 Tube joint set type M 100 pairs/set
080200-0831 Tube joint attachment tool type M If the number of particles in the measurement environment is small, the ratio of the number
080200-084 Sampling tube (pair tube) 1.5 m x 5 of particles inside and outside the mask is reduced, so even if the mask is fitted correctly,
it may fail the test.
The particle generator increases the number of particles in the measurement environment
■Options by spraying distilled water in which salt tablets are dissolved to ensure that pass/fail judgments
Item code Item name using the MT-05U are appropriately made.
080200-075 Particle generator * Prepare the PET bottle separately.
080200-0751 Salt tablets (100 each/bottle)
080200-085 Test guide 10 pcs/set
● Specifications and appearance described in this document are based on information as of April 2019. ● The color of actual products may differ to that color in this data sheet.
● Before using MT-05U, please read the operation manual.