1/2ページ
カタログの表紙
カタログの表紙

このカタログをダウンロードして
すべてを見る

ダウンロード(481.6Kb)

X67 I/O System overview

製品カタログ

B&R X67 system - Mount, connect and you‘re ready to go

Remote I/O with IP67 protection
With a credit card design and IP67 rating provi- ding protection in the harshest industrial environ- ments, this new dimension in remote I/O techno- logy can be installed directly in the machine room, freeing up valuable space in the control cabinet and working just as fast as a centralized soluti- on. Experience ultimate freedom in your choice of communication fieldbus with the advanced X67 I/O system.

このカタログについて

ドキュメント名 X67 I/O System overview
ドキュメント種別 製品カタログ
ファイルサイズ 481.6Kb
取り扱い企業 B&R株式会社 (この企業の取り扱いカタログ一覧)

このカタログの内容

Page1

B&R X67 system - Integrated automation Mount, connect and you‘re Global presence X67 I/O ready to go Solid partnership System overview Remote I/O with IP67 protection The shortest commissioning times With a credit card design and IP67 rating provi- Pre-assembled standard cables make it possible ding protection in the harshest industrial environ- for the mechanic to make the necessary connec- ments, this new dimension in remote I/O techno- tions himself, relegating wiring errors to history logy can be installed directly in the machine room, where they belong. Commissioning can begin im- freeing up valuable space in the control cabinet mediately when machine construction is started, and working just as fast as a centralized soluti- with time-consuming inspection of the wiring no on. Experience ultimate freedom in your choice of longer necessary. communication fieldbus with the advanced X67 I/O system. Minimized service costs Correcting errors is easy since individual sensors Traditional I/O systems are located centrally in the and actuators can be quickly replaced using plug control cabinet, with extensive wiring required for connections. Extensive diagnostic functions al- sensors and actuators. In addition, modular machi- low errors to be detected immediately. ne designs often require intermediate connections with multi-pin connectors. Remote I/O modules can One system for all machine designs only reach their full potential, however, if additional Whether a compact machine or an extensive system, distribution boxes can be eliminated completely. this I/O system can be adapted to the machine‘s ar- This is why the optimal solution has to include I/O chitecture to meet every possible demand. modules with robust IP67 protection that can be placed directly in harsh industrial environments. Highlights Reduced wiring Instead of having to extensively wire each indi- < Compact and ergonomic vidual sensor or actuator to the control cabinet < IP67 protection over long distances, the X67 system reduces the < Excellent EMC properties amount of work down to a single bus cable and < Open for all fieldbus systems a 24 VDC power supply. This applies to the entire < Seamless integration of IP20-rated I/O B&R Corporate HeadquartersBernecker + Rainer B&R Strasse 1 t +43 7748 6586-0 office@br-automation.com Your local contact machine and cuts costs considerably. Industrie-Elektronik Ges.m.b.H. 5142 Eggelsberg, Austria f +43 7748 6586-26 www.br-automation.com www.br-automation.com/contact MM-E01343.084 © 11/2013 by B&R. All rights reserved worldwide.
Page2

X67 Digital M8 standard M8 high-density Digital M12 M12 high-density Analog M12 standard Miscellaneous M12 standard Bus controllers M8 standard M8 high-density M12 high-density inputs/outputs inputs/outputs inputs/outputs Digital inputs X67DI1371.L12 X67AI1223 X67DC1198 X67BC8321-1 X67BC8321.L12 - 16 inputs 4 inputs 2 SSI absolute encoders 5 VDC or 8 digital channels 16 digital channels X67DI1371 X67DI1371.L08 24 VDC Sink 12-bit 8 inputs 16 inputs Analog inputs 2 ABR incremental encoders 5 VDC, configurable as inputs configurable as inputs Sink Sink ±10 V 4 AB counters or or outputs or outputs X67DO9332.L12 X67AI1233 4 up/down counters 24 VDC, Digital inputs Digital outputs 8 outputs 4 inputs 2x pulse width modulation, - X67BC8513.L12 - 2 A nominal output current 16-bit time measurement, X67BC8331 12 digital channels 24 VDC 24 VDC Source Counting relative timestamp 8 digital channels configurable as inputs Node number switch X67AI1323 configurable as inputs or outputs X67DI1372 4 inputs or outputs 1 analog input, 0 to 20 mA, 8 inputs Analog inputs 12-bit 12-bit Source X67DM1321.L12 16 inputs/outputs 0 to 20 or 4 to 20 mA X67DC2322 X67AI1333 2 resolver inputs, X67BC7321-1 0.5 A nominal output current 4 inputs 2 digital inputs, CAN I/O 8 digital channels Software filter 16-bit 2 digital outputs configurable as inputs - - Event counter or outputs Gate measurement Analog inputs X67AI4850 X67DO1332 Potentiometer 4 inputs Digital outputs 8 outputs displacement gauge 14-bit X67BC4321-1 X67BC4321.L08-1 X67BC4321.L12-10 24 VDC 2 A nominal output current - X67DM9321.L12 X67IF1121-1 8 digital channels 16 digital channels 16 digital channels Source Digital 16 inputs/outputs 1x RS232 or 1x RS485/RS422, X67AI2744 configurable as inputs configurable as inputs configurable as inputs inputs/outputs - 0.5 A nominal output current Analog inputs Communication 2 digital inputs, 2 inputs or outputs or outputs or outputsSoftware filter 24 VDC Strain gauge 2 digital channels configurable Node number switch 24-bit as inputs or outputs CANopen Event counter X67AO1223 X67BC4321-10 X67BC4321.L08-10Gate measurement Analog outputs 4 outputs 8 digital channels 16 digital channels X67DM1321 X67DM1321.L08 ±10 V 12-bit configurable as inputs configurable as inputs 8 inputs/outputs 16 inputs/outputs X67DM9331.L12 X67UM1352 or outputs or outputs 0.5 A nominal output current 0.5 A nominal output current 8 inputs/outputs X67AO1323 4 digital inputs, 24 VDC, sink Analog outputs Software filter Software filter 2 A nominal output current 4 outputs Combination 2 digital outputs, 24 VDC, source X67BC5321 Event counter Event counter Sofware filter 0 to 20 mA 12-bit 0.5/1 A nominal output current 8 digital channels Gate measurement Gate measurement - -Node number switch 1 strain gauge DeviceNet configurable as inputs Analog inputs/outputs X67AM1223 or outputs Digital 2 inputs/2 outputs 7XV108.50-51 X67DV1311.L12 ±10 V 12-bit X67SM2436 inputs/outputs 8 valves 16 inputs, sink, software filter 2 full bridges for controlling stepper motors X67BCD321.L12 24 VDC 16 outputs, source Analog inputs/outputs X67AM1323 2x3 inputs for ABR incremental encoder EtherNet/IP - - 16 digital channels 7XV108.50-62 0.1 A nominal output current 2 inputs/2 outputs 24 to 38.5 VDC ±25% configurable as inputs X67DM9321 8 valves 0 to 20 mA 12-bit 3 A or outputs 8 inputs/outputs (5 A peak) 0.5 A nominal output current 7XV116.50-51 Software filter X67AT1311 X67BCJ321 X67BCJ321.L12 16 valves 8 digital channels 16 digital channels Node number switch 4 inputs Modbus TCP/UDP - 16-bit X67SM4320 configurable as inputs configurable as inputs Event counter Gate measurement Valve control 7XV116.50-62 PT100 4 full bridges for controlling stepper motors Temperature or outputs or outputs 16 valves Motor control 24 VDC ±25%24 VDC resistance 1 A X67AT1322 (1.5 A peak) X67BC6321 X67BC6321.L08 X67BC6321.L12 7XV124.50-51 measurement 4 inputs 8 digital channels 16 digital channels 16 digital channels 24 valves PROfIBUS DP16-bit configurable as inputs configurable as inputs configurable as inputs X67DV1311.L08 KTY10-6, KTY84-130, X67MM2436 or outputs or outputs or outputs Valve control 16 inputs, sink, 7XV124.50-61 PT100 or PT1000 2 channels PWM output (H bridge) - software filter 24 valves 2x3 inputs for ABR incremental encoder X67BCE321.L12 24 VDC 16 outputs, source Temperature X67AT1402 24 to 38.5 VDC ±25% PROfINET RT - - 16 digital channels 0.1 A nominal output current 7XV124.50-62 4 inputs 3 Athermocouple configurable as inputs 24 valves 16-bit (5 A peak) or outputs