Page1
MGSD-10080F
8-Port 100/1000X SFP + 2-Port 10/100/1000T
Managed Metro Ethernet Switch
Physical Port
• 8 100/1000Base-X SFP mini-GBIC slots
• 2-Port 10/100/1000Base-T Gigabit Ethernet RJ-45
• One RJ-45 console interface for basic management
and setup
Redundant Power System
• Redundant Power System: 100V ~ 240V AC / Dual
36V ~ 72V DC
Multiple SFP Fiber Port Switch for Growing Long-Reach Networking of • Active-active redundant power failure protection
Enterprise, Telecoms and Campus • Backup of catastrophic power failure on one supply
The PLANET latest Metro series Ethernet switch MGSD-10080F is equipped with • Fault tolerance and resilience.
advanced management functions and provides 8 100/1000Mbps dual speed SFP
Fiber ports, and 2 10/100/1000Mbps TP ports delivered in a rugged strong case.
Digital Input / Digital Output
It is capable of providing non-blocking switch fabric and wire-speed throughput
as high as 20Gbps in the temperature range from -10 to 60 degrees C without • 2 Digital Input (DI)
any packet loss and CRC error, which greatly simplify the tasks of upgrading the • 2 Digital Output (DO)
enterprise LAN for catering to increasing bandwidth demands. The MGSD-10080F • Integrates sensors into auto alarm system
is specially designed for service provider to deliver profitable long distance Ethernet • Transfer alarm to IP network via SNMP trap
network. The MGSD-10080F adopts “Front Access” design, making the wiring and
maintenance of the MGSD-10080F placed in a cabinet very easy for technicians.
Hardware Design
• -10 to 60 degrees C operating temperature for DC
power input only
AC Power Input System / PWR / Port L.E.D.
and Switch 2 x DI / DO 8 x 100/1000Base-X SFP Slot • 13-inch desktop size, 19-inch Rack-mountable
• Relay alarm for port breakdown, power failure
• Fanless design
Layer 2 Features
• Prevents packet loss with back pressure (Half-Duplex)
Grounding 2 x DC Power Inputs 2 x 10/100/1000Base-T, RJ-45 and IEEE 802.3x PAUSE frame flow control
DC Power Switch Reset Button RJ-45-to-DB9 Console
(Full-Duplex)
• High performance of Store-and-Forward architecture
and runt/CRC filtering eliminate erroneous packets to
optimize the network bandwidth
• Storm Control support
– Broadcast / Multicast / Unicast
Data Sheet
1 1
Page2
MGSD-10080F
• Supports VLAN
Flexible and Extendable Solution – IEEE 802.1Q Tagged VLAN
The 8 mini-GBIC slots built in the MGSD-10080F support Dual-Speed, 100Base- – Up to 255 VLANs groups, out of 4094 VLAN IDs
FX and 1000Base-SX/LX SFP (Small Form-factor Pluggable) fiber-optic modules, – Provider Bridging (VLAN Q-in-Q) support (IEEE
meaning the administrator now can flexibly choose the suitable SFP transceiver
according to the transmission distance or the transmission speed required to 802.1ad)
extend the network efficiently. The MGSD-10080F supports SFP-DDM (Digital – Private VLAN Edge (PVE)
Diagnostic Monitor) function that can easily monitor real-time parameters of the – Protocol-based VLAN
SFP for network administrator, such as optical output power, optical input power,
– MAC-based VLAN
temperature, laser bias current, and transceiver supply voltage.
– Voice VLAN
• Supports Spanning Tree Protocol
Digital Diagnostic Monitor (DDM) – STP, IEEE 802.1D Spanning Tree Protocol
Voltage – RSTP, IEEE 802.1w Rapid Spanning Tree Protocol
150 Ammeter – MSTP, IEEE 802.1s Multiple Spanning Tree
100 200
30
50 250 20 40 Protocol, spanning tree by VLAN
0 300 10 50
V – BPDU Guard
0 60
A
• Supports Link Aggregation
Temperature
– 802.3ad Link Aggregation Control Protocol (LACP)
– Cisco ether-channel (Static Trunk)
°C – Maximum 5 trunk groups, up to 8 ports per trunk
0 group
−20 20
0
−20 20 −40 40
−40 40 −60 60 – Up to 16Gbps bandwidth (Duplex Mode)
−60 60
dBm
dBm • Provides Port Mirror (1-to-1)
Power Transceiver
Power Receiver • Port Mirroring to monitor the incoming or outgoing
traffic on a particular port
• Loop protection to avoid broadcast loops
AC and DC Redundant Power to Ensure Continuous Operation Quality of Service
To enhance the operation reliability and flexibility, the MGSD-10080F is equipped
• Ingress Shaper and Egress Rate Limit per port
with one 100 ~ 240V AC power supply unit and two additional 36 ~ 72V DC power
input connectors for redundant power supply installation. The Redundant Power bandwidth control
Systems are specifically designed to handle the demands of high tech facilities • 8 priority queues on all switch ports
requiring the highest power integrity. Furthermore, with the 36 ~ 72V DC power • Traffic classification
supply implemented, the MGSD-10080F can be applied as the telecom level device
– IEEE 802.1p CoS
that could be located in the electronic room.
– IP TOS / DSCP / IP Precedence
– IP TCP/UDP port number
Digital Input and Digital Output for External Alarm
– Typical network application
The MGSD-10080F supports Digital Input, and Digital Output on the front panel.
The external alarm offers technicians the ability to use Digital Input to detect, and • Strict priority and Weighted Round Robin (WRR) CoS
log external device status (such as door intrusion detector) for the alarm as Digital policies
Output could be used to alarm if the MGSD-10080F has port link down, link up or
power failure.
2
Page3
MGSD-10080F
Digital Input
• Supports QoS and In/Out bandwidth control on each port
• Traffic-policing policies on the switch port
• DSCP remarking
I/O
O SNMP
O I/I/
I/O TRAP
Enclosure Enclosure Mail System
Door Detector Door Detector Log
(Door Close) (Door Open) Multicast
Security OK!! Alarm Warning Alarm Messaging
• Supports IGMP Snooping v1, v2 and v3
Digital Output • Supports MLD Snooping v1 and v2
• Querier mode support
I/O I/O
I/O I/O • IGMP Snooping port filtering
• MLD Snooping port filtering
• MVR (Multicast VLAN Registration)
Security
Fiber Cable RJ-45 Cable
AC Power DC Power Failure Link Down Link Down
Failure • IEEE 802.1x Port-based / MAC-based network access
authentication
• Built-in RADIUS client to co-operate with the RADIUS
Cost-effective IPv6 Managed Gigabit Switch Solution for Metro Ethernet servers
To fulfill the demand for ISP to build up the IPv6 (Internet Protocol version 6) • RADIUS / TACACS+ users access authentication
network infrastructure speedily, the MGSD-10080F supports both IPv4 and IPv6 • IP-based Access Control List (ACL)
management functions. It can work with original IPv4 network structure and also
• MAC-based Access Control List
support the new IPv6 network structure. With easy and friendly management
interfaces and plenty of management functions included, the MGSD-10080F Metro • Source MAC / IP address binding
Ethernet Switch is the best choice for ISP and service providers to build the IPv6 • DHCP Snooping to filter untrusted DHCP messages
FTTx edge service and for Industries to connect with IPv6 network. • Dynamic ARP Inspection discards ARP packets with
invalid MAC address to IP address binding
Layer 2 / Layer 4 Full-functioned Managed Switch for Building • IP Source Guard prevents IP spoofing attacks
Automation Networking • IP address access management to prevent
The MGSD-10080F Managed Ethernet Switch is also ideal for applications in the unauthorized intruder
factory data centers and distributions. It provides advanced Layer 2 to Layer 4
data switching and redundancy, Quality of Service traffic control, network access
control and authentication, and secure management features to protect customer’s Management
Automation Ethernet network connectivity with reliable switching recovery capability • Switch Management Interfaces
that is suitable for implementing fault tolerant and mesh network architectures.
– Console / Telnet Command Line Interface
– Web switch management
Powerful Security – SNMP v1 and v2c switch management
The MGSD-10080F offers comprehensive Access Control List (ACL) for enforcing
– SSH / SSL and SNMP v3 secure access
security to the edge. Its protection mechanisms also comprise port-based 802.1x
and MAC-based user and device authentication. The port-security is effective in • Four RMON groups (history, statistics, alarms, and
limiting the numbers of clients passing through, so that network administrators can events)
now construct highly secured corporate networks with time and effort considerably • IPv6 IP Address / NTP / DNS management
less than before.
• Built-in Trivial File Transfer Protocol (TFTP) client
3
Page4
MGSD-10080F
Application
Optimized Design for Metropolitan Area Network
By means of improving the technology of Optical Fiber Ethernet with high-flexible, • BOOTP and DHCP for IP address assignment
high-extendable and easy-installation features, the MGSD-10080F offers the data
• Firmware upload / download via HTTP / TFTP
exchange speed of Optical Fiber up to 1Gbps, and the distance of Gigabit Optical
Fiber up to 120km. It supports service providers, such as ISP and Telecom, to • DHCP Relay
install Metropolitan Area Network (MAN) based on Fiber technology to the WAN • DHCP Option 82
Internet Service. • User Privilege levels control
• NTP (Network Time Protocol)
Metropolitan Area Network Application • Link Layer Discovery Protocol (LLDP) Protocol
• SFP-DDM (Digital Diagnostic Monitor)
City D
• Cable Diagnostic technology provides the mechanism
City B to detect and report potential cabling issues
120km
1000
• Reset button for system reboot or reset to factory
MGSD-10080F
default
City A
MGSD-10080F 1000 • PLANET Smart Discovery Utility for deploy
120km
1000 1000 management
City E
120km 1000
MGSD-10080F 1000
1000
City C
120km MGSD-10080F
1000
Spanning Tree
Redundant Connection
MGSD-10080F
1000 1000Base-SX/LX Fiber-optic
Excellent Solution of Core / Department Switch
With 10 Gigabit ports, the MGSD-10080F is able to connect up to 10 edge
switches in the Ethernet environment. Moreover, the MGSD-10080F provides 20
Gigabit per second switch fabric and high bandwidth for backbone connection. The
MGSD-10080F is an excellent choice of core layer switch for a Gigabit network.
Central Office
Branch Office B
Branch Office A
20F/SAM MGSD-10080F
1000
10F/ENM
1000
1000
MGSD-10080F
MGSD-10080F
1000
3F/Control Center
120km
1000 1000Base-SX/LX Fiber-optic
4
Page5
MGSD-10080F
Product Specifications
Model MGSD-10080F
Hardware Specification
8 1000Base-SX/LX/BX SFP interfaces, from port 1 to port 8
SFP/mini-GBIC Slots
Compatible with 100Base-FX SFP
Copper Ports 2 10/ 100/1000Base-T RJ-45 Auto-MDI/MDI-X ports
Console Port 1 x RJ-45-to-RS-232 serial port (115200, 8, N, 1)
Switch Architecture Store-and-Forward
Throughput (packet per second) 14.8Mpps @ 64Bytes packet
Switch Fabric 20Gbps / non-blocking
Address Table 8K entries, automatic source address learning and ageing
Share Data Buffer 4Mbits
IEEE 802.3x Pause Frame for Full-Duplex
Flow Control
Back pressure for Half-Duplex
Jumbo Frame 9Kbytes
< 5 seconds: System Reboot
Reset Button
> 10 seconds: Factory Default
Dimensions (W x D x H) 330 x 155 x 43.5 mm, 1U high
Weight 1661g
System:
PWR (Green)
DC 1 (Green)
DC 2 (Green)
Fault Alarm (Green)
LED Indicator
Ring* (Green)
Ring Owner* (Green)
Per Gigabit Ports:
100 LNK/ACT (Orange)
1000 LNK/ACT (Green)
Max. 11.2 Watts / 38.2 BTU (AC input)
Power Consumption
Max. 10.8 Watts / 36.9 BTU (DC input)
AC 100~240V, 50/60Hz 0.15A
Power Requirements
-36V DC @ 0.3A, Range: -36V ~ -72V DC
Alarm One relay output for power failure. Alarm Relay current carry ability: 1A @ DC 24V
2 Digital Input (DI) : Level 0: -24V~2.1V (±0.1V)
Level 1: 2.1V~24V (±0.1V)
DI/DO
Input Load to 24V DC, 10mA max.
2 Digital Output (DO) : Open collector to 24VDC, 100mA max.
Layer 2 Function
Port disable / enable
Auto-Negotiation 10/100/1000Mbps full and half duplex mode selection
Port Configuration Flow Control disable / enable
Bandwidth control on each port
Power saving mode control
Display each port’s speed duplex mode, link status, flow control status,
Port Status
auto negotiation status, trunk status
TX / RX / Both
Port Mirroring
1 to 1 monitor
802.1Q Tagged Based VLAN, up to 255 VLAN groups
Q-in-Q tunneling
Private VLAN Edge (PVE)
MAC-based VLAN
VLAN
Protocol-based VLAN
Voice VLAN
MVR (Multicast VLAN Registration)
Up to 255 VLAN groups, out of 4094 VLAN IDs
IEEE 802.3ad LACP / Static Trunk
Link Aggregation
Supports 5 groups of 8-Port trunk support
5
Page6
MGSD-10080F
Traffic classification based, Strict priority and WRR
8-Level priority for switching
- Port Number
QoS
- 802.1p priority
- 802.1Q VLAN tag
- DSCP/TOS field in IP Packet
IGMP (v1/v2/V3) Snooping, up to 255 multicast Groups
IGMP Snooping
IGMP Querier mode support
MLD (v1/v2) Snooping, up to 255 multicast Groups
MLD Snooping
MLD Querier mode support
IP-based ACL / MAC-based ACL
Access Control List
Up to 123 entries
Per port bandwidth control
Bandwidth Control Ingress: 500Kb~1000Mbps
Egress: 500Kb~1000Mbps
Management
Basic Management Interfaces Console, Telnet, Web Browser, SNMP v1, v2c and v3
Secure Management Interface SSH, SSL, SNMP v3
RFC-1213 MIB-II
IF-MIB
RFC-1493 Bridge MIB
RFC-1643 Ethernet MIB
RFC-2863 Interface MIB
RFC-2665 Ether-Like MIB
RFC-2819 RMON MIB (Group 1)
SNMP MIBs
RFC-2737 Entity MIB
RFC-2618 RADIUS Client MIB
RFC-2933 IGMP-STD-MIB
RFC-3411 SNMP-Frameworks-MIB
IEEE 802.1X PAE
LLDP
MAU-MIB
Standards Conformance
Regulation Compliance FCC Part 15 Class A, CE
IEEE 802.3 10Base-T
IEEE 802.3u 100Base-TX/100Base-FX
IEEE 802.3z Gigabit SX/LX
IEEE 802.3ab Gigabit 1000T
IEEE 802.3x Flow Control and Back pressure
IEEE 802.3ad Port trunk with LACP
IEEE 802.1D Spanning tree protocol
IEEE 802.1w Rapid Spanning tree protocol
IEEE 802.1s Multiple Spanning tree protocol
IEEE 802.1p Class of service
Standards Compliance
IEEE 802.1Q VLAN Tagging
IEEE 802.1x Port Authentication Network Control
IEEE 802.1ab LLDP
RFC 768 UDP
RFC 793 TFTP
RFC 791 IP
RFC 792 ICMP
RFC 2068 HTTP
RFC 1112 IGMP version 1
RFC 2236 IGMP version 2
Environment
Temperature : -10 ~ 60 degrees C for DC power input
Operating 0 ~ 50 degrees C for AC power input
Relative Humidity : 5 ~ 95% (non-condensing)
Temperature: -10 ~ 70 degrees C
Storage
Relative Humidity: 5 ~ 95% (non-condensing)
6
Page7
MGSD-10080F
Ordering Information
MGSD-10080F 8-Port 100/1000X SFP + 2-Port 10/100/1000T Managed Metro Ethernet Switch
Available Modules for MGSD-10080F
• 1000Mbps SFP transceiver modules
MGB-GT SFP-Port 1000Base-T Module
MGB-SX SFP-Port 1000Base-SX mini-GBIC module - 550m
MGB-SX2 SFP-Port 1000Base-SX mini-GBIC module - 2km
MGB-LX SFP-Port 1000Base-LX mini-GBIC module - 10km
MGB-L30 SFP-Port 1000Base-LX mini-GBIC module - 30km
MGB-L50 SFP-Port 1000Base-LX mini-GBIC module - 50km
MGB-L70 SFP-Port 1000Base-LX mini-GBIC module - 70km
MGB-L120 SFP-Port 1000Base-LX mini-GBIC module - 120km
MGB-LA10 SFP-Port 1000Base-LX (WDM,TX:1310nm) mini-GBIC module - 10km
MGB-LB10 SFP-Port 1000Base-LX (WDM,TX:1550nm) mini-GBIC module - 10km
MGB-LA20 SFP-Port 1000Base-LX (WDM,TX:1310nm) mini-GBIC module - 20km
MGB-LB20 SFP-Port 1000Base-LX (WDM,TX:1550nm) mini-GBIC module - 20km
MGB-LA40 SFP-Port 1000Base-LX (WDM,TX:1310nm) mini-GBIC module - 40km
MGB-LB40 SFP-Port 1000Base-LX (WDM,TX:1550nm) mini-GBIC module - 40km
MGB-TSX SFP-Port 1000Base-SX mini-GBIC module - 550m (-40 ~ 75 degrees C)
MGB-TLX SFP-Port 1000Base-LX mini-GBIC module - 10km (-40 ~ 75 degrees C)
MGB-TL30 SFP-Port 1000Base-LX mini-GBIC module - 30km (-40 ~ 75 degrees C)
MGB-TL70 SFP-Port 1000Base-LX mini-GBIC module - 70km (-40 ~ 75 degrees C)
• 100Mbps SFP transceiver modules
MFB-FX SFP-Port 100Base-FX Transceiver (1310nm) - 2km
MFB-F20 SFP-Port 100Base-FX Transceiver (1310nm) - 20km
MFB-F40 SFP-Port 100Base-FX Transceiver (1310nm) - 40km
MFB-F60 SFP-Port 100Base-FX Transceiver (1310nm) - 60km
MFB-FA20 SFP-Port 100Base-BX Transceiver (WDM,TX:1310nm) - 20km
MFB-FB20 SFP-Port 100Base-BX Transceiver (WDM,TX:1550nm) - 20km
MFB-TFX SFP-Port 100Base-FX Transceiver (1310nm) - 2km (-40 ~ 75 degrees C)
MFB-TF20 SFP-Port 100Base-FX Transceiver (1310nm) - 20km (-40 ~ 75 degrees C)
PLANET Technology Corporation
11F., No.96, Minquan Rd., Xindian Dist., New Taipei City MGSD-10080F
231, Taiwan (R.O.C.)
PLANET reserves the right to change specifications without prior notice. All brand names and trademarks are property of
Tel: 886-2-2219-9518 Fax: 886-2-2219-9528 their respective owners. Copyright © 2013 PLANET Technology Corp. All rights reserved.
Email: sales@planet.com.tw www.planet.com.tw
7