1/8ページ
ダウンロード(3.1Mb)
0155 IP67 マネージド イーサネットスイッチ
6ポート10/100/1000T マネージドスイッチ, M12コネクタ, -40-75℃
このカタログについて
ドキュメント名 | 産業用イーサネットスイッチ PLANET IGS-5227-6T |
---|---|
ドキュメント種別 | 製品カタログ |
ファイルサイズ | 3.1Mb |
登録カテゴリ | |
取り扱い企業 | サンテックス株式会社 (この企業の取り扱いカタログ一覧) |
この企業の関連カタログ
![](https://static.cluez.biz/common/img/base/loading.gif)
このカタログの内容
Page1
IGS-5227-6T
Industrial IP67-rated 6-Port 10/100/1000T Managed
Ethernet Switch (-40~75 degrees C)
Physical Port
• 6-port 10/100/1000BASE-T waterproof and dustproof
RJ45 copper
Hardware Conformance
• IP67-rated aluminum case
• Redundant power design
– 9 to 48V DC, redundant power with polarity reverse
protect function
– Active-active redundant power failure protection
– Backup of catastrophic power failure on one supply
– Fault tolerance and resilience
– 24V AC power input acceptable
Performance Not Affected by Industrial Conditions
PLANET IGS-5227-6T Industrial Managed Ethernet Switch comes with an IP67- • DIN-rail and wall-mount design
rated industrial case, 6-port 10/100/1000T, and static Layer 3 routing, providing • Supports Ethernet ESD protection of 6000V DC
a high level of immunity against electromagnetic interference and heavy electrical • -40 to 75 degrees C operating temperature
surges which are usually found on plant floors or in curb-side traffic control
cabinets. The IGS-5227-6T can be easily mounted on a DIN rail or wall taking up Layer 3 IP Routing Features
less space. It provides a quick, safe, cost-effective and high-performance network • Supports maximum 32 static routes and route
solution to IP security surveillance for small businesses and enterprises. summarization
IP67 Rugged Case Layer 2 Features
• Prevents packet loss with back pressure (half-duplex) and
IEEE 802.3x pause frame flow control (full-duplex)
• High performance of Store-and-Forward architecture, and
runt/CRC filtering that eliminates erroneous packets to
6 x Waterproof Gigabit RJ45 optimize the network bandwidth
• Storm control support
– Broadcast/Multicast/Unicast
• Supports VLAN
– IEEE 802.1Q tagged VLAN
9~48V DC, 24V DC Waterproof
Redundant Power Input – Up to 255 VLANs groups, out of 4095 VLAN IDs
– Provides Bridging (VLAN Q-in-Q) support (IEEE
802.1ad)
– Private VLAN Edge (PVE)
Waterproof and Dustproof RJ45 Ethernet Connector and Shielded Plug – Protocol-based VLAN
The IGS-5227-6T is equipped with a 6-port 10/100/1000BASE-T auto-negotiation – MAC-based VLAN
waterproof and dustproof RJ45 connector. These shielded RJ45 plugs can – IP subnet-based VLAN
make the general UTP cable waterproof and dustproof. When connected to the – Voice VLAN
waterproof and dustproof RJ45 connector, it provides tight and strong connection, • Supports Spanning Tree Protocol
and comes with the industrial protection rating of IP67 capable of withstanding – IEEE 802.1D Spanning Tree Protocol (STP)
humidity, dirt, dust, shock, vibrations, heat and cold. – IEEE 802.1w Rapid Spanning Tree Protocol (RSTP)
– IEEE 802.1s Multiple Spanning Tree Protocol (MSTP),
spanning tree by VLAN
– BPDU Guard
1
Page2
IGS-5227-6T
• Supports Link Aggregation
– 802.3ad Link Aggregation Control Protocol (LACP)
– Cisco ether-channel (static trunk)
– Maximum 3 trunk groups, with 2 ports for each trunk
– Up to 4Gbps bandwidth (full duplex mode)
• Provides port mirror (many-to-1)
• Port mirroring monitors the incoming or outgoing traffic on
a particular port
• Loop protection to avoid broadcast loops
• Supports E.R.P.S. (Ethernet Ring Protection Switching)
Environmentally Hardened Design • IEEE 1588 and Synchronous Ethernet network timing
The IGS-5227-6T is able to protect itself from dust and water ingress, and to operate
under the temperature range from -40 to 75 degrees C. All these features ensure the Quality of Service
highest level of reliability for mission-critical applications in any difficult environment. • Ingress shaper and egress rate limit per port bandwidth
control
• 8 priority queues on all switch ports
• Traffic classification
– IEEE 802.1p CoS
– ToS/DSCP/IP precedence of IPv4/IPv6 packets
– IP TCP/UDP port number
– Typical network application
• Strict priority and Weighted Round Robin (WRR) CoS
policies
• Traffic-policing policies on the switch port
Dual Power Input for High Availability Network System • DSCP remarking
The IGS-5227-6T features a strong dual power input system (Dual 9~48V DC, 24V
AC) incorporated into customer’s automation network to enhance system reliability and Multicast
uptime. For example, when DC Power 1 fails to work, the hardware failover function • Supports IGMP snooping v1, v2 and v3
will be activated automatically to keep powering the IGS-5227-6T via DC Power 2 • Supports MLD snooping v1 and v2
alternatively without any loss of operation.
• Querier mode support
• IGMP snooping port filtering
SMTP/SNMP Trap Event Alert
Though most NVR or camera management software offers SMTP email alert function, • MLD snooping port filtering
the IGS-5227-6T further provides event alert function to help to diagnose the abnormal • MVR (Multicast VLAN Registration)
device owing to whether or not there is a break of the network connection, or loss of
power. Security
SMTP/SNMP Trap Event Alert • Authentication
– IEEE 802.1x port-based/MAC-based network access
IGS-5227-6T
authentication
E-mail Alert
– IEEE 802.1x authentication with guest VLAN
– Built-in RADIUS client to cooperate with the RADIUS
Malfunction servers
– RADIUS/TACACS+ users access authentication
• Access Control List
– IP-based Access Control List (ACL)
– MAC-based Access Control List (ACL)
IP Camera IP Camera
2
Page3
IGS-5227-6T
Featuring Fast Recovery for Critical Network Applications • Source MAC/IP address binding
The IGS-5227-6T supports redundant ring technology and features strong, rapid self- • DHCP Snooping to filter distrusted DHCP messages
recovery capability to prevent interruptions and external intrusions. It incorporates • Dynamic ARP Inspection discards ARP packets with
advanced ITU-T G.8032 ERPS (Ethernet Ring Protection Switching) technology, invalid MAC address to IP address binding
Spanning Tree Protocol (802.1s MSTP), and redundant power input system into
• IP Source Guard prevents IP spoofing attacks
customer’s industrial automation network to enhance system reliability and uptime in
• IP address access management to prevent unauthorized
harsh factory environments. In a certain, simple Ring network, the recovery time of data
intruder
link is within 20ms.
Management
Office
Factory • IPv4 and IPv6 dual stack management
1000 • Switch Management Interfaces
Industrial MAN Switch – Telnet command line interface
Industrial 10G Switch – Web switch management
1000 – SNMP v1, v2c, and v3 switch management
E.R.P.S. Ring for Metropolitan Area Network Application – SSH/SSL secure access
Recovery Time < 50ms
• IPv6 address/NTP management
• Built-in Trivial File Transfer Protocol (TFTP) client
• BOOTP and DHCP for IP address assignment
• System Maintenance
– Firmware upload/download via HTTP/TFTP
8-port MAN Switch – Reset button for system reboot or reset to factory default
IGS-5227-6T
Control Center – Dual images
Highway • DHCP relay and option 82
IPv6/IPv4 Dual Stack • User privilege levels control
Supporting both IPv6 and IPv4 protocols, the IGS-5227-6T helps data centers, • NTP (Network Time Protocol)
campuses, telecoms, and more to experience the IPv6 era with the lowest investment as • Link Layer Discovery Protocol (LLDP) and LLDP-MED
its network facilities need not be replaced or overhauled if the IPv6 FTTx edge network • Network diagnostic
is set up. – Cable diagnostic technology provides the mechanism to
detect and report potential cabling issues
Layer 3 IPv4 and IPv6 VLAN Routing for Secure and Flexible Management – ICMPv6/ICMPv4 remote ping
The IGS-5227-6T not only provides ultra high transmission performance, and excellent • SMTP/Syslog remote alarm
Layer 2 and Layer 4 technologies, but also Layer 3 IPv4/IPv6 VLAN routing feature • Four RMON groups (history, statistics, alarms and events)
which allows to cross over different VLANs and different IP addresses for the purpose of • SNMP trap for interface link up and link down notification
having a highly-secure, flexibly-managed and simple networking application.
• PLANET Smart Discovery Utility for deployment
management
Robust Layer 2 Features
The IGS-5227-6T can be programmed for advanced switch management functions such
as dynamic port link aggregation, Q-in-Q VLAN, private VLAN, Multiple Spanning
Tree Protocol (MSTP), Layer 2 to Layer 4 QoS, bandwidth control and IGMP/MLD
Snooping. Via the link aggregation of supporting ports, the IGS-5227-6T allows the
operation of a high-speed trunk to combine with multiple fiber ports and supports fail-
over as well.
MSTP LACP
Q-in-Q QoS LLDP
MLD IGMP
L2/L4 L2/L4
Managed Switch Managed Switch
3
Page4
IGS-5227-6T
Powerful Security
The Switch offers a comprehensive Layer 2 to Layer 4 Access Control List (ACL) for enforcing security to the edge. It can be used to restrict network
access by denying packets based on source and destination IP address, TCP/UDP ports or defined typical network applications. Its protection mechanism
also comprises 802.1X Port-based and MAC-based user, and device authentication. With the private VLAN function, communication between edge ports
can be prevented to ensure user privacy. The IGS-5227-6T also provides DHCP Snooping, IP Source Guard and Dynamic ARP Inspection functions to
prevent IP snooping from attack and discard ARP packets with invalid MAC address. The network administrators can now construct highly-secure corporate
networks with considerably less time and effort than before.
Excellent Traffic Control
The IGS-5227-6T is loaded with powerful traffic management and QoS features to enhance connection services by telecoms and ISPs. The QoS features
include wire-speed Layer 4 traffic classifiers and bandwidth limit that are particularly useful for multi-tenant units, multi-business units, Telco and network
service providers’ applications. It also empowers the industrial environment to take full advantage of the limited network resources and guarantees the best
performance in VoIP and video conferencing transmission.
Efficient and Secure Management
With built-in Web-based management interface, the IGS-5227-6T L2+ Managed Switch offers an easy-to-use, platform-independent management and
configuration facility which includes Web and SNMP management interfaces. The SNMP can be managed via any management software based on the
standard of SNMP Protocol. For reducing product learning time, it offers Cisco-like command via Telnet and customer does not need to learn new console
command. Moreover, it also offers secure remote management by supporting SSH, SSL and SNMP v3 connections which encrypt the packet content at each
session.
IGS-5227-6T
01010101010110010101010100010101010
01010101010110010101010100010101010
01010101010110010101010100010101010
Computer
SSL SNMPv3 SSH
1588 Time Protocol for Industrial Computing Networks
The IGS-5227 series is ideal for telecom and Carrier Ethernet applications, supporting MEF service delivery and timing over packet solutions for IEEE 1588
and synchronous Ethernet.
Modbus TCP provides Flexible Network Connectivity for Factory Automation
With the supported Modbus TCP/IP protocol, the IGS-5227 series can easily integrate with SCADA systems, HMI systems and other data acquisition
systems in factory floors. It enable administrators to remotely monitor the industrial Ethernet switch’s operating information, port information and
communication status, thus easily achieving enhanced monitoring and maintenance of the entire factory.
4
Page5
IGS-5227-6T
Applications
High Availability Networking Solution for Surveillance System
The Switch has the capability to rapidly recover itself in case there are interruptions or external instrusions. As the ITU-T G.8032 ERPS is employed,
the reliability and uptime of the network can be greatly enhanced. Thus, the IGS-5227-6T, with its redundant connection and high bandwidth, is ideal for
building an IP-based surveillance infrastructure in public transportation.
Control Center
IGS-5227-6T IGS-5227-6T
IGS-5227-6T
Dual Band AP Dual Band AP
ERPS Ring
Recovery time <50 ms
IP Camera IP Camera
Railway Platform
100BASE-TX UTP
1000BASE-T UTP
Layer 2+ VLAN Static Routing
With the built-in robust Layer 3 routing protocols, the IGS-5227-6T ensures reliable routing between VLANs and network segments. The routing protocols
can be applied by VLAN interface with up to 32 routing entries. The IGS-5227-6T, certainly an ideal solution for industries, offers greater security, control
and bandwidth conservation, and high-speed uplink.
IP Surveillance Domain Wireless AP Domain
192.168.10.x/24 Industrial IP67-rated 192.168.20.x/24
Ethernet Switch
NVR
IGS-5227-6T
IP Camera Dual Band Wireless AP
1000BASE-T UTP
5
Page6
IGS-5227-6T
Specifications
Product IGS-5227-6T
Hardware Specifications
Copper Ports 6 10/100/1000BASE-T waterproof and dustproof RJ45 auto-MDI/MDI-X ports
Switch Architecture Store-and-Forward
Switch Fabric 12Gbps/non-blocking
Throughput 8.9Mpps@64bytes
Address Table 8K entries, automatic source address learning and aging
Shared Data Buffer 4M bits
IEEE 802.3x pause frame for full-duplex
Flow Control
Back pressure for half-duplex
Jumbo Frame 9K bytes
< 5 sec: System reboot
Reset Button
> 5 sec: Factory default
Dimensions (W x D x H) 103 x 68.3 x 163 mm
Weight 1069g
System:
DC1 (Green), DC2 (Green), Fault (Red)
LED Ring (Green), R.O. (Green)
10/100/1000T RJ45 Interfaces
LNK/ACT (Green)
Power Consumption Max. 8.3 watts/ 28.5 BTU
Power Requirements Dual 9~48V DC, 24V AC
ESD Protection 6KV DC
Layer 2 Management Functions
Port disable/enable
Port Configuration Auto-negotiation 10/100/1000Mbps full and half duplex mode selection
Flow control disable/enable
Port Status Display each port’s speed duplex mode, link status, flow control status, auto-negotiation status, trunk status
TX/RX/Both
Port Mirroring
Many-to-1 monitor
802.1Q tagged based VLAN
Q-in-Q tunneling
Private VLAN Edge (PVE)
MAC-based VLAN
VLAN Protocol-based VLAN
Voice VLAN
IP Subnet-based VLAN
MVR (Multicast VLAN registration)
Up to 255 VLAN groups, out of 4095 VLAN IDs
IEEE 802.3ad LACP/static trunk
Link Aggregation
3 groups with 2 port per trunk
IEEE 802.1D Spanning Tree Protocol (STP)
Spanning Tree Protocol IEEE 802.1w Rapid Spanning Tree Protocol (RSTP)
IEEE 802.1s Multiple Spanning Tree Protocol (MSTP)
IGMP snooping v1, v2, v3, up to 255 multicast groups
IGMP Snooping
IGMP querier mode support
MLD snooping v1, v2, up to 255 multicast groups
MLD Snooping
MLD querier mode support
IP-based ACL/MAC-based ACL
Access Control List
Up to 256 entries
Per port bandwidth control
Bandwidth Control Ingress: 100Kbps~1000Mbps
Egress: 100Kbps~1000Mbps
Layer 3 Functions
IP Interfaces Max. 8 VLAN interfaces
Routing Table Max. 32 routing entries
IPv4 software static routing
Routing Protocols
IPv6 software static routing
6
Page7
IGS-5227-6T
Management
Basic Management Interfaces Telnet/Web browser/SNMP v1, v2c
Secure Management Interfaces SSH, SSL, SNMP v3
RFC 1213 MIB-II RFC 2863 IF-MIB
RFC 1493 Bridge MIB RFC 2933 IGMP-STD-MIB
RFC 1643 Ethernet MIB RFC 3411 SNMP-Frameworks-MIB
RFC 2863 Interface MIB RFC 4292 IP Forward MIB
SNMP MIBs
RFC 2665 Ether-Like MIB RFC 4293 IP MIB
RFC 2819 RMON MIB (Group 1, 2, 3 and 9) RFC 4836 MAU-MIB
RFC 2737 Entity MIB IEEE 802.1X PAE
RFC 2618 RADIUS Client MIB LLDP
Standards Conformance
Regulatory Compliance FCC Part 15 Class A, CE
IEC60068-2-32 (free fall)
Stability Testing IEC60068-2-27 (shock)
IEC60068-2-6 (vibration)
IEEE 802.3 10BASE-T IEEE 802.1ab LLDP
IEEE 802.3u 100BASE-TX RFC 768 UDP
IEEE 802.3ab Gigabit 1000T RFC 793 TFTP
IEEE 802.3x flow control and back pressure RFC 791 IP
IEEE 802.3ad port trunk with LACP RFC 792 ICMP
Standards Compliance IEEE 802.1D Spanning Tree Protocol RFC 2068 HTTP
IEEE 802.1w Rapid Spanning Tree Protocol RFC 1112 IGMP v1
IEEE 802.1s Multiple Spanning Tree Protocol RFC 2236 IGMP v2
IEEE 802.1p Class of Service RFC 3376 IGMP v3
IEEE 802.1Q VLAN tagging RFC 2710 MLD v1
IEEE 802.1X Port Authentication Network Control FRC 3810 MLD v2
Environment
Temperature: -40 ~ 75 degrees C
Operating
Relative Humidity: 5 ~ 95% (non-condensing)
Temperature: -40 ~ 80 degrees C
Storage
Relative Humidity: 5 ~ 95% (non-condensing)
Drawing
LNK/ACT
LNK
ACT
1 2
LNK/ACT
3 4
LNK/ACT
5 6
V2 V1
FAULT V2 V1
PWR 2 R.O.
PWR 1 Ring
INPUT IP67 Mgt.
DC 9~48V IGS-5227-6T
Dimensions (unit = mm)
7
Page8
IGS-5227-6T
Ordering Information
IGS-5227-6T Industrial IP67-rated 6-Port 10/100/1000T Managed Ethernet Switch (-40~75 degrees C)
Related Products
IGS-5227-6MT Industrial IP67-rated 6-Port 10/100/1000T M12 Managed Ethernet Switch(-40~75 degrees C, A-coded M12)
IGS-5227-6MT-X Industrial IP67-rated 6-Port 10/100/1000T M12 Managed Ethernet Switch (-40~75 degrees C, X-coded M12)
IGS-604HPT-RJ Industrial IP67-rated 4-Port 10/100/1000T 802.3at PoE + 2-Port 10/100/1000T Managed Ethernet Switch (-40~75 degrees C)
IGS-604HPT-M12 Industrial IP67-rated 4-Port 10/100/1000T 802.3at PoE + 2-Port 10/100/1000T Managed Ethernet Switch (-40~75 degrees C)
IGS-5226-4P2T Industrial EN50155 4-Port 10/100/1000T 802.3at PoE + 2-Port 10/100/1000T Managed Ethernet Switch (-40~75 degrees C)
ISW-800T-M12 Industrial IP67-rated 8-Port 10/100Mbps M12 Ethernet Switch (-40~75 degrees C)
ISW-804PT-M12 Industrial IP67-rated 8-Port 10/100Mbps M12 Ethernet Switch with 4-Port PoE (-40~75 degrees C)
PLANET Technology Corporation
11F., No.96, Minquan Rd., Xindian Dist., New Taipei City IGS-5227-6T
231, Taiwan (R.O.C.)
PLANET reserves the right to change specifications without prior notice. All brand names and trademarks are property of
Tel: 886-2-2219-9518 Fax: 886-2-2219-9528 their respective owners. Copyright © 2017 PLANET Technology Corp. All rights reserved.
Email: sales@planet.com.tw www.planet.com.tw
8